NovaJet 800 Series Service Manual

4 Vertical

*

Cancel

 

Next Option

 

 

<selected>

Prev Option

Ok

Figure 3-21. 4 Vertical Options Menu.

5.Observe the plot and using either “Prev Option” or “Next Option”, rotate through the selections until the one that best aligns the cartridge in slot 4 on the plot is selected. Press “Ok” to accept the selection and return to the Color Calib Menu.

6.Continue until all seven vertical calibrations on the Color Calib Menu have been accomplished.

7.To make adjustments to the horizontal alignments, follow similiar procedures as those above but replace “vertical” with “horizontal”. The Horizontal Color Calibration printout is shown on the lower half of Figure 3-18.

Deadband Alignments

Deadband calibration compensates for minute differences created when bidirectional printing is used. Unidirectional printing is not affected by deadband. There are four types of deadband tests:

Deadband

Slow Deadband

All Lines Tests

Single Line Test

Maintenance 3-34

Page 86
Image 86
Kodak 800 SERIES service manual Deadband Alignments, Selected