NovaJet 800 Series Service Manual

3.Place the test cartridge upright on a flat surface and ‘zero’ the gauge by loosening the knob near the top and turning the dial until the needle is at the ‘0’ position on the dial. Tighten the knob. See Figure 3-16.

ZERO

ENSURE PRESSURE IS

PLACED ON THE REAR

GAUGE

OF THE CARTRIDGE

 

Figure 3-16. Zeroing the Micrometer Gauge.

4.Remove the Cyan ink cartridge. Snap the test cartridge with the micrometer gauge into the position vacated by the Cyan ink cartridge. See Figure 3-17. Ensure that the micrometer can be read from the BACK of the printer.

Figure 3-17. Test Cartridge Installed.

5.Slightly loosen the 6 screws located on the back of the Y-arm that secures the stabilizer to the Y-arm.