NovaJet 800 Series Service Manual

2.Ensure the reservoirs are attached to female valves properly at left end of printer or this may cause ink starvation in the ink delivery system after 10 minutes of print operations.

Figure 4-65. Cartridge Tubing Needle and Septum.

3.Ensure the septum connector assembly is tightly secure. The assembly is composed of three parts which must be tightly twisted together prior to installation and use.

4.Ensure the septum connector/cartridge tubing needle is properly connected between the cartridge and carriage assembly - you may have to reseat the assembly at the valve body. Replace reservoir tubing needle and/or cartridge tubing needle if pressure is lost after the procedure has been performed (a leak is present in the line).

5.Replace the cartridge with a new one. Re-prime the line.

6.If ink cannot be pulled through the line using the EasyPrime device ensure the device is functioning correctly by verifying suction and check the 4 AA batteries in the unit.

7.Always run a color test @100% in the 2 pass print mode to verify the proper pressure levels have been achieved within the cartridge.

Troubleshooting 4-62

Page 161
Image 161
Kodak 800 SERIES service manual Cartridge Tubing Needle and Septum