NovaJet 800 Series Service Manual

Failure Analysis

1.Is the Encoder Strip clean? Has any image skewing occurred prior to the carriage axis error? If skewing resumes following a cleaning within a day or two then the encoder strip is damaged and must be replaced. Normally the encoder strip cleanings should carry the unit through 7 day/24 hour operation for a minimum of 2 weeks without error. Refer to disassembly to replace the encoder stabilizer bracket and the trailing cables.

Figure 4-75. Dirty or Defective Encoder Strip.

Inspect encoder strip for damage - if error occurs in one spot consistently then the encoder strip could be damaged. Replace the stabilizer bracket (encoder strip is pre-attached to stabilizer bracket) and obtain a new trailing cable assembly for installation.

2.Check outrigger carriage cover bushings for visible wear and replace outrigger bushings at 400 hours of printing operation. To replace the cover bushings refer to disassembly procedures. While replacing inspect and verify the internal right and left carriage bushings are not severely worn (normally replaced at 2000 plot hours).

3.Is the Slide Shaft clean? Check with printer operator to see if lubricants have been applied to slide shaft - no lubricants should be applied to any part of the printer.

Troubleshooting 4-72

Page 171
Image 171
Kodak 800 SERIES service manual Dirty or Defective Encoder Strip