NovaJet 800 Series Service Manual

5.Lift out the left side of the Service Station from the Platen and remove the Service Station. Moving the Service Station farther to the right might be required to release the left side of the Service Station.

Install the Service Station

1.To install the Service Station, position the Service Station inside the Right Cover and place the left side of the Service Station into the Platen.

2.Push down on the right side of the Service Station until the Service Station snaps into place.

3.Slide the Carriage Assembly to the right and back into the home position. Lower the Top Cover.

Remove the Trailing Cable Assembly

1.Remove the Top, Left and Right Covers following procedures outlined earlier in this chapter.

2.Position the Carriage Assembly to the right side of the center of the Slide Shaft. Make sure that the Chain Guide on the Chain Support Bracket is not blocking the Floating Carriage Cover or it may be very difficult to perform these procedures.

3.Remove the three screws securing the Left Support Bracket to the Floating Cover. Slide the Left Support Bracket to the left, away from the Carriage Assembly and Floating Carriage Cover. Carefully move the Floating Carriage Cover/Right Support Bracket Assembly to the right.

4.Remove the Electronics Covers and release the left end of the Trailing Cables from the Carriage PWAs.

5.Release the Strain Reliefs (with the Trailing Cables and ferrite attached) from the Carriages.

6.Disconnect the Trailing Cable Assembly connectors at the J1 and J2 locations on the Main PWA. Use the thumb and forefinger to pull forward on the connector lock and remove the Trailing Cables from their connectors. See Figure 3-6.

Assembly\Disassembly 5-41

Page 245
Image 245
Kodak 800 SERIES service manual Install the Service Station, Remove the Trailing Cable Assembly