NovaJet 800 Series Service Manual

Trailing Cables Cleaning

Clean the trailing cables bi- weekly or as necessary to remove any buildup of debris. Distilled water should be used. Do not pull too hard on the trailing cables or damage may occur.

To clean the Trailing Cables:

1.Disconnect the power cord and interface cable.

2.Slightly dampen a lint-free cloth with water and wipe along the length of the trailing cables on both sides. Ensure the encoder stabilizer bracket surface is thoroughly cleaned. Clean the lower surface of the rear cover on the left side of the printer.

3.Reconnect the power cord and interface cable.

Platen/Vacuum Hole Cleaning

To clean the external surfaces of the printer. Dampen a lint-free cloth with water and wipe all surfaces of ink and debris. Ensure the platen surface is thoroughly cleaned.

To clean the platen vacuum holes obtain a toothpick and gently remove lint and media fiber from platen holes. Caution: do not push lint through platen holes or problems with the stepper motor gearing may eventually occur leading to microbanding in image output.

If the platen holes are not cleaned periodically then adequate vacuum suction be not be available to pull media down during print operations.

MAINTENANCE

Maintenance 3-5

Page 57
Image 57
Kodak 800 SERIES service manual Trailing Cables Cleaning, Platen/Vacuum Hole Cleaning, To clean the Trailing Cables