12.To adjust the far right screw obtain the head height plate and install into the service station access hole (service station must be removed). Move the carriage assembly over the service station access hole so the Micrometer measuring tip extends to the head height plate surface. Adjust for 67 +/-3 reading the RED number only.

13.Continue performing steps 10 through 12 until all six of the stabilizer screws have been adjusted.

14.Reposition the Carriage to all of the adjustment positions and verify that the measurements are correct.

15.Perform steps 6 through 15 as many times as necessary to correctly accomplish this adjustment.

Color Calibration

This procedure describes how to check that the cartridges are properly aligned for color plotting and should be followed each time the ink car- tridges are installed. Figure 3-18 is a representation of how a color calibration looks when printed.