NovaJet 800 Series Service Manual

NOTE

Some units may have very small servicing loops in the wir- ing of the Dryer Assembly. When removing the Right Endcap, the possibility exists that a connection may have been pulled loose elsewhere within the body of the dryer if extreme force is used to pull the endcap away from the main body. During assembly, ensure that all internal con- nections are good, including connections located at the left side of the dryer.

5.Disconnect the ground connection from the power cord to the main body of Thermal Dryer.

6.Disconnect all other connections going from the main body to the printed wiring assembly.

Install the Thermal Dryer Right Endcap Assembly

NOTE

Some of the units may have very small servicing loops in the wiring of the Dryer Assembly. When removing the Right Endcap, the possibility exists that a connection may have been pulled loose elsewhere within the body of the dryer if extreme force is used to pull the endcap away from the main body. During assembly, ensure that all internal con- nections are good, including connections located at the left side of the dryer.

1.Reconnect all the connections going from the main body to the printed wiring assembly on the Right Endcap Assembly. See Figure 5-36 and Table 5-1.

Assembly\Disassembly 5-64

Page 268
Image 268
Kodak 800 SERIES service manual Install the Thermal Dryer Right Endcap Assembly