6.Observe the plot and using either “Prev Option” or “Next Option”, rotate through the selections until one that seems closer to the correct value is selected. Press “Ok” to accept the selection and return to the Left Carriage Cartridge Slot Selection Menu.

7.Continue performing steps 4 through 6 until the all color deadband adjustments are correct on the left carriage.

8.To make adjustments to the right carriage deadband alignments, follow similiar procedures as those above but replace “left” with “right”.

Paper Axis Calibration

The paper axis calibration procedure ensures that the processing that drives the stepper motor is correct to minimize line length accuracy errors.

To perform the paper axis procedure:

1.Select “Utility Menu” from the Main Menu. This brings up the Utility Menu as shown in Figure 3-19.

2.From the Utility Menu, select “Calibration Menu”. This brings up the Calibration Menu as shown in Figure 3-25.

3.From the Calibration Menu, select “Use Paper Calib.” Ensure that Use Paper Calib is set to ON and press “Ok.” This allows the printer to store the data that is entered in step 7.

4.From the Calibration Menu, select “Paper Axis Test”. This runs the paper axis test which prints out two “T” figures that are mirrored from each other and about 33” (83.82 cm) apart. See Figure 3-27.