Figure 3-5. Carriage PWA Connection Locations.

 

Table 3-2. Carriage PWA Connections.

J1

Trailing Cable

J5

Cyan/Slot 2 Drivers

J2

Paper Sensor

J6

Magenta/Slot 3 Drivers

J3

Encoder Sensor

J7

Yellow/Slot 4 Drivers

J4

Black/Slot 1 Drivers

 

 

Figures 3-4 and 3-5 show the locations of all the connectors on the Main PWA and carriage boards respectively. The J2 and J3 jack connections shown on Figure 3-5 are used on the right carriage assem- bly only.

To remove the ribbon cables from their connectors, lift the connector’s ribbon locking mechanism as shown in Figure 3-6. To reattach, depress the locking mechanism back into the locking position after inserting the ribbon cable end.

MAINTENANCE

Maintenance 3-11

Page 63
Image 63
Kodak 800 SERIES service manual Carriage PWA Connection Locations