Maintenance 3-11
NovaJet 800 Series Service Manual
MAINTENANCE
J7
J6
J4
J5 J3
J2
J1
Figure 3-5. Carriage PWA Connection Locations.
Table 3-2. Carriage PWA Connections.
J1 Trailing Cable J5 Cyan/Slot 2 Drivers
J2 Paper Sensor J6 Magenta/Slot 3 Drivers
J3 Encoder Sensor J7 Yellow/Slot 4 Drivers
J4 Black/Slot 1 Drivers
Figures 3-4 and 3-5 show the locations of all the connectors on the
Main PWA and carriage boards respectively. The J2 and J3 jack
connections shown on Figure 3-5 are used on the right carriage assem-
bly only.
To remove the ribbon cables from their connectors, lift the connector’s
ribbon locking mechanism as shown in Figure 3-6. To reattach, depress
the locking mechanism back into the locking position after inserting the
ribbon cable end.