NovaJet 800 Series Service Manual

Calibration Jo Block (1.434”)

- Not used

Plastic Gauge Card (0.011”)

- Not used

There are two basic measurements that are to be made using this kit (ensure power is off prior to performing these proceures):

1.Slide Shaft Profile Adjustment

2.Carriage (Cartridge) Head Height Setting

1.Connect the dial gauge micrometer to the Shaft mounting block as shown in Figure 3-11.

MAINTENANCE

ZERO

GAUGE

TIGHTEN SET

SCREW (NOT

SHOWN)

SHAFT MOUNTING BLOCK

Figure 3-11. Dial Gauge Micrometer Assembly.

2. Place gauge against left side of shaft assembly allowing micrometer tip to rest directly on top of shaft. See Figure 3-12. Zero the gauge (this is to become the reference point).

Maintenance 3-25