NovaJet 800 Series Service Manual

of the dialog box. Give the new folder a name and press OK.

7.Now press the Add button in the Files section of the dialog box. Find the firmware file that you downloaded from Encad’s website and press the Open button. This will add the firmware file to the folder you created.

8.Select the firmware file in the Files section of the dialog box and press the Print button.

The firmware file is sent to the printer as a normal print job. Approxi- mately 20 - 40 seconds later a single beep should be heard indicating the update was successful. After a one second delay, the printer will auto- matically reboot. The printer should come up normally. Verify the new firmware revision by sequencing through Utility Menu/Service Menu/ About Menu. If multiple beeps are heard, reboot printer and reseat your connection to the printer (network cable or parallel cable). Resend the firmware file to the printer.

Note: the parallel cable should not exceed 6 feet or 2 meters. NT workstations do not support the required ECP parallel port mode unless a PCI card has been installed and configured for ECP parallel port data transfer.

Caution: Turn off printer before connecting the IEEE 1284 compliant parallel printer cable to printer or damage to Printer’s Main circuit board may result !

Troubleshooting 4-102