NovaJet 800 Series Service Manual

SEH

Blue test button

IP ADDRESS 192.168.2.10

Figure 4-89. SEH Activated Test Pattern.

Figure 4-90. E-Connect LEDs.

4.For data or communications problems to the printer check parallel port interface by running a E-Connect Test (quickly depress Test Button at rear of printer at E-Connect Box) or run a continuous test with loopback cable attached (not provided with printer). Refer to the ‘Parallel Port Test’. The Semi-Circular Nook test pattern will print. This will ensure the network server, parallel printer ports, the short parallel printer cable (15”/39 cm), and the Main PWA processor are functioning correctly.

NOTE: The yellow (100) LED should be illuminated indicating a 100baseT network is online. As long as the green LED is illuminated printer operations should be successful.

Troubleshooting 4-87

Page 186
Image 186
Kodak 800 SERIES service manual SEH Activated Test Pattern