NovaJet 800 Series Service Manual

CAUTION

Failure to use an approved antistatic bag for storage or shipment may cause damage to the Main PWA and affect the Warranty.

17.Place the Main PWA in an ESD bag (antistatic bag) in preparation for shipment to ENCAD for replacement or repair, or if it is to be stored at your facility for repair.

Install the Main Printed Wiring Assembly (PWA)

CAUTION

Integrated circuits may become weakened or damaged by electrical discharge. Do not touch or work near integrated circuits without wearing an ESD wrist strap.

1.Put on an ESD wrist strap.

2.Remove the Main PWA from the ESD bag.

3.Align the Main PWA so that the serial and parallel connections protrude out of the back of the printer and that the screw holes are aligned to the holes on the power supply bracket.

4.Fasten the Main PWA to the power supply bracket with 8 in-lb of torque. Ensure that the ground straps from the side plate and baseplate are secured to the Main PWA by the screw located beside the side plate nearest to the parallel port.

5.Connect the E-Connect Power connector to J18 on the Main PWA.

6.Connect the Power Supply Cooling Fan connector to J17 on the Main PWA.

7.Connect the Vacuum Fan 2 (60 inch only) connector to J4 on the Main PWA.

Assembly\Disassembly 5-14

Page 218
Image 218
Kodak 800 SERIES service manual Install the Main Printed Wiring Assembly PWA