SCC 2-Pump 12-Station Controllers
Asia/Australia +86 512 8717 1919
Sales and Contracting Department
Shipping Information
Page
Table of Contents
CHAPTER 1: SAFETY ................................................................6
CHAPTER 2: FUNCTIONAL DESCRIPTION............................ 10
CHAPTER 3: INSTALLATION ..................................................14
CHAPTER 4: OPERATION ........................................................34
CHAPTER 5: MAINTENANCE................................................... 43
CHAPTER 6: TROUBLESHOOTING......................................... 46
CHAPTER 7: APPENDIX ..........................................................49
CHAPTER 8: SERVICE ONLY INFORMATION ........................57
Chapter 1: Safety
1-1 How to Use This Manual
Danger!
Warning!
Caution!
1-2 Warnings and Precautions
1-3 Responsibility
Page
Chapter 2: Functional Description
2-1 Models Covered in This Manual
2-2 General Description
2-3 Standard Features
2-4 Optional Features
2-5 Safety Devices and Interlocks
Page
Chapter 3: Installation
3-1 Uncrating
3-2 Mounting the Control Panel
3-3 Electrical Connections
Page
2Pump 12-Station Controllers Chapter 3: Installation 16
Figure 1: Typical 24-Volt Junction Box Wiring Diagram
WIRE LUG
FIELD WIRING
INTERNAL
3-4 Setup
Page
STATION SETTINGS? NO/YES
OPERATION MODE? NO/YES
ALL NORMAL MODE? NO/YES
ALL SIGHTGLASS MODE? NO/YES
STATION: 1 NORMAL Y=NORMAL N=SIGHTGLS
SET DUMP DELAY? NO/YES
DUMP DELAY 11: 15.0s PRESS ENTER TO SAVE
SET INPUT DELAY? NO/YES
INPUT DLY 11: 0.250s PRESS ENTER TO SAVE
SET STATION ALARMS? NO/YES
ALARM 11: ENABLED Y=ENABLE N=DISABLE
ALARM AFTER 3 LOADS PRESS ENTER TO SAVE
STATION SETTINGS? NO/YES
ASSIGN PUMP>STATION? NO/YES
PRESS HOPPER <1-12>
STATION 10: PUMP 1 SELECT PUMP 1 OR 2
PUMP SETTINGS? NO/YES
PUMP MODE? NO/YES
SET PUMP MODE? Y=SINGLE N=DUAL
SET ACTIVE PUMP SELECT PUMP 1 OR 2
BLOWBACK SETTINGS? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
ENABLE BLOWBACK? NO/YES
BLOWBACK PULSES: 10 SETTING FOR PUMP 1
ON TIME: 0.500 s SETTING FOR PUMP 1
OFF TIME: 0.500 s SETTING FOR PUMP 1
BLBK AFTER 12 LOADS SETTING FOR PUMP 1
IDLE DELAY TIME? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
IDLE TIME: 10.000 s SETTING FOR PUMP 1
3-5 Initial Startup
LOAD TIME 10: 63sec PRESS ENTER TO SAVE
Chapter 4: Operation
4-1 Startup
SECTION 1 SECTION 2 SECTION 3 SECTION 4
4-2 Controller Description and Operation
STATION:-- OFFLINE TIME: --- LOGO
P1:S--:--- OFFLINE P2:S-:--- OFFLINE
Page
Page
Page
4-3 Operation
Page
Page
Chapter 5: Maintenance
2Pump 12-Station Controllers Chapter 5: Maintenance 44
Figure 5: BIOS Connection, Electrical Diagram; Drawing 1
SCHAFFNER - FN1394-10-05-11
N
2Pump 12-Station Controllers Chapter 5: Maintenance 45
Figure 6: BIOS Connection, Electrical Diagram; Drawing 2
A0560970 LEGEND
Chapter 6: Troubleshooting
6-1 General Troubleshooting
Page
WRITING PARAMETERS TO FLASH-PLEASE WAIT
SAVING BACKUP TO FLASH-PLEASE WAIT
Chapter 7: Appendix
7-1 Warranty
Page
Page
7-3 Spare Parts List
Page
Page
Page
7-4 Controller Identification (Serial Number) Tag
7-5 Technical Assistance (Contact Information)
SET RAMP UP TIME? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
RAMP UP DLY: 1.500s SETTING FOR PUMP n
Chapter 8: Service Only Information
8-1 Service Settings Menu
SET RAMP DOWN TIME? NO/YES
RAMP DN DLY: 8.000s SETTING FOR PUMP n
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
SET PUMP STAGE TIME? NO/YES
STAGE DELAY: 3.000s PRESS ENTER TO SAVE
SET LCD BLINK DELAY? NO/YES
BLINK DELAY: .500s PRESS ENTER TO SAVE
HI VAC SENSOR DELAY? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
HIVAC DELAY: 3.000s SETTING FOR PUMP n
HI VAC VENT DELAY? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
HV VENT DLY: 10.000s SETTING FOR PUMP n
HI VAC LOAD COUNT? NO/YES
SELECT PUMP 1 OR 2 USE KEYPAD TO ENTER
HV LOAD CNT: 7 SETTING FOR PUMP n
INPUT MONITOR? NO/YES
IN BNK0: 0000000000 IN BNK1: 0000000000
OUTPUT CONTROL? NO/YES
AUTOMATIC OR MANUAL? N=AUTO Y=MANUAL
OUTBNK0: 0000000000 OUTBNK1: 0000000000
OEM MENU ACCESS IS NOW AVAILABLE!
OEM SETTINGS? NO/YES
8-2 Other Controller Restricted Areas
PWL1:1111 PWL2:2222 PWL3:3333 PWL4:4444
ROM CHECKSUM: 0x0000 PRESS YES TO RESUME