Output Control Menu

The Output Control menu gives you direct access to all 20 outputs of the controller. The menu has two (2) modes: Manual and Automatic. Automatic mode cycles each output on and off. Manual mode gives you access to each individual output.

OUTPUT CONTROL?

NO/YES

At the above message prompt:

1.Press the YES key to enter the Output Control menu. The following screen displays.

AUTOMATIC OR MANUAL?

N=AUTO Y=MANUAL

To start the automatic cycle:

Press the NO key.

To increase speed:

Press the START/STOP key. To decrease speed:

Press the SET key.

To exit the Output Control menu and turn all outputs OFF: 2. Press the CLEAR key.

Caution! Automatically cycling outputs with the pump in Active mode can damage the conveying system.

Caution! Do not perform this action unless directed to do so by the Service Department.

2–Pump 12-Station Controllers

Chapter 8: Service Only Information