Station Icons

Below the text portion of the screen, 12 station icons display the status of each station in the system. Each station icon contains four segments.

Figure 3: Station Icon Segments

Label

Description

Segment 1

The top segment indicates the status of the valve above each station. When

 

the valve is open (control output energized), this icon highlights. In Single

 

Pump mode, only one valve indicator is active at a time. In Dual Pump

 

mode, up to two valve indicators can be active at a time. When this

 

indicator flashes, it indicates the assignment of a priority convey.

 

 

Segment 2

The center square segment indicates the existence of a station specific alarm

 

condition. The alarm is typically related to a No Convey condition, but can

 

also indicate the station with a high vacuum condition.

 

 

Segment 3

Located on the bottom of the station icon, the lower segment indicates the

 

station demand input. This is a real time indicator, displaying when the

 

station demand input is active. This indicator may toggle on and off during

 

the load cycle, and should be considered normal.

 

 

Segment 4

Segment 4 is the indicator word ON, located below the station icon. When

 

ON displays, the related station loads when the system senses a demand

 

signal. When ON does not display, the station demand input signal is

 

ignored and the related station does not load. Segment 4 blinks with

 

Segment 2 in a high vacuum condition.

 

 