Setting the Hi Vacuum Load Count

Hi vacuum load count sets the maximum number of loads on a station in a high vacuum condition. If a station repeatedly experiences a high vacuum condition for the selected number of loads without being cleared or attended to, it goes off line to prevent damage to the conveying system. This parameter defaults to 7 loads and should not be altered unless you are instructed to do so by the Service Department.

HI VAC LOAD COUNT?

NO/YES

At the above message prompt:

1. Press the YES key to enter the Hi Vacuum Load Count menu.

SELECT PUMP 1 OR 2

USE KEYPAD TO ENTER

At the above screen prompt:

2.Select the pump for altering the high vacuum load count. The following screen displays.

HV LOAD CNT: 7

SETTING FOR PUMP n

Using the keypad:

3. Enter the new time and press the ENTER key to save the new setting.

2–Pump 12-Station Controllers

Chapter 8: Service Only Information

63