Sterling 882.00249.00 manual Blowback SETTINGS? NO/YES, Select Pump 1 or USE Keypad to Enter

Models: 882.00249.00

1 70
Download 70 pages 6.71 Kb
Page 30
Image 30

Changing Blowback Settings, Pump Settings Menu

As an option, you can equip the conveying system filter chamber with a blowback feature to pulsate compressed air through the filter. This function cleans the filter after a pre-set number of load sequences.

To set up the controller blowback feature, enter the Pump Settings menu, then:

Press the MENU key until the Blowback Settings prompt screen displays:

BLOWBACK SETTINGS?

NO/YES

Press the YES key to alter the blowback settings. The following screen displays.

SELECT PUMP 1 OR 2

USE KEYPAD TO ENTER

Each pump can have separate blowback settings. To alter pump settings, select a pump:

Using the keypad, enter the pump number (1 or 2). The following screen displays.

ENABLE BLOWBACK?

NO/YES

To disable the blowback feature:

Press the NO key.

The screen returns to the Pump Settings menu.

If you want to enable the blowback feature:

Press the YES key.

2–Pump 12-Station Controllers

Chapter 3: Installation

29

Page 30
Image 30
Sterling 882.00249.00 manual Blowback SETTINGS? NO/YES, Select Pump 1 or USE Keypad to Enter, Enable BLOWBACK? NO/YES