Changing Blowback Settings, Pump Settings Menu

As an option, you can equip the conveying system filter chamber with a blowback feature to pulsate compressed air through the filter. This function cleans the filter after a pre-set number of load sequences.

To set up the controller blowback feature, enter the Pump Settings menu, then:

Press the MENU key until the Blowback Settings prompt screen displays:

BLOWBACK SETTINGS?

NO/YES

Press the YES key to alter the blowback settings. The following screen displays.

SELECT PUMP 1 OR 2

USE KEYPAD TO ENTER

Each pump can have separate blowback settings. To alter pump settings, select a pump:

Using the keypad, enter the pump number (1 or 2). The following screen displays.

ENABLE BLOWBACK?

NO/YES

To disable the blowback feature:

Press the NO key.

The screen returns to the Pump Settings menu.

If you want to enable the blowback feature:

Press the YES key.