Each station has its own No Convey alarm settings. You can enable or disable alarms as needed. If a station doesn’t receive (or dump) material after a user definable number of load attempts, the controller activates an alarm condition. Perform the following procedure to set alarm conditions.

To alter the Input Delay time:

Press the YES key. The following screen displays.

TO SELECT A STATION

PRESS STATION <1-12>

To alter stations alarm settings:

Select a station to alter, then press the related Station STnn key. nn is the station number you selected.

The screen displays the selected station (11 in the following example) and the current station alarm setting.

ALARM 11: ENABLED

Y=ENABLE N=DISABLE

To enable the alarm:

Press the YES key.

The alarm is enabled on the station you selected.

If you want to disable the alarm:

Press the NO key.

The alarm is disabled on the station you selected.

The controller increments to the next station in sequence.

To retain the original setting:

Press the SET key.

The next station in the sequence displays.