Write Down Your Serial Numbers Here For Future Reference
SCC 2-Pump 12-Station Controllers
Parts and Service Department
If the Shipment is Not Complete
Shipping Information
Unpacking and Inspection
Event of Shipping Damage
Returns
Warranty Returns
Credit Returns
Table of Contents
Maintenance
How to Use This Manual
Safety
Safety Symbols Used in this Manual
Wear Safety Glasses and Work Gloves
Controller Safety Tags
General Responsibility
Responsibility
Reporting a Safety Defect
Maintenance Responsibility
Operator Responsibility
Models Covered in This Manual
Functional Description
General Description
Electrical Features
Standard Features
Optional Features
Mechanical Features
Fail Safe Operation
Safety Devices and Interlocks
Safety Circuit Standards
Safety Device Lock-Outs
Pump 12-Station Controllers Functional Description
Mounting the Control Panel
Installation
Making Control Panel Power Drop Wiring Connections
Uncrating
Connecting the Control Panel to the Pump Package
Connecting the Control Panel to Vacuum Hoppers
Typical 24-Volt Junction Box Wiring Diagram
Inputs
Setup
Main Power
DC Controller Power Sources
Menu Tree Structure
Gaining Access to the Menu System
Operation MODE? NO/YES
Station SETTINGS? NO/YES
Station Settings Menu
Operation Mode, Station Settings Menu
ALL Sightglass MODE? NO/YES
ALL Normal MODE? NO/YES
Station 1 Normal =NORMAL N=SIGHTGLS
To Select a Station Press Station
SET Dump DELAY? NO/YES
Dump Delay 11 15.0s
Set Dump Delay, Station Settings Menu
Set Input Delay, Station Settings Menu
SET Input DELAY? NO/YES
Set Station Alarms, Station Settings Menu
SET Station ALARMS? NO/YES
Input DLY 11 0.250s
Alarm 11 Enabled =ENABLE N=DISABLE
Assigning a Pump to a Station
Alarm After 3 Loads Press Enter to Save
Assign PUMPSTATION? NO/YES
To Select a Station Press Hopper
Station 10 Pump Select Pump 1 or
Pump MODE? NO/YES
Pump SETTINGS? NO/YES
Pump Settings Menu
Setting the Pump Mode
SET Active Pump Select Pump 1 or
Select Pump 1 or USE Keypad to Enter
Blowback SETTINGS? NO/YES
Enable BLOWBACK? NO/YES
Changing Blowback Settings, Pump Settings Menu
On Time 0.500 s
Blowback Pulses Setting for Pump
OFF Time 0.500 s
Idle Delay TIME? NO/YES
Blbk After 12 Loads Setting for Pump
Idle Delay Time Settings, Pump Settings Menu
Idle Time 10.000 s
System Settings Menu
Saving Controller Settings to Flash Memory
Service Settings Menu
Load Time 10 63sec
Operation
Controller Description and Operation
Section
Text Area
P1S----- Offline P2S----- Offline
Pump Modes Single Pump Mode
Dual Pump Mode
STATION-- Offline Time --- Logo
Station Icon Segments Label Description
Station Icons
Status Indicator Icons Label Description
Status Indicators
Key Descriptions
Controller Keypad
Label Description
Operation States
Operation
Runs but no station loads
Shut-Down
Updating Bios Software
Maintenance
Bios Connection, Electrical Diagram Drawing
A0560970LEGEND
General Troubleshooting
Troubleshooting
See -5 on Page 75 for
Controller Recovery using Flash Memory Technology
Writing Parameters To FLASH-PLEASE Wait Saving Backup
Appendix
Warranty
Warranty Specifications
Warranty Restrictions
Customer Responsibilities
Warranty Liabilities
Pump 12 station Controller Control Panel
Drawings and Diagrams
Places A0560974 Power cord A0560954
Spare Parts List
ENCL, CARLON, Mount FLNG, MNK10L
A0560974
RECT, BRIDGE, 25 AMPS, GBPC2510
Technical Assistance Contact Information
Controller Identification Serial Number Tag
Setting the Ramp Up Time
Service Only Information
Ramp UP DLY 1.500s Setting for Pump n
Service Settings Menu
Setting the Ramp Down Time
Ramp DN DLY 8.000s Setting for Pump n
SET Ramp Down TIME? NO/YES
Setting the Pump Stage Time
Stage Delay 3.000s
SET Pump Stage TIME? NO/YES
Blink Delay .500s
SET LCD Blink DELAY? NO/YES
Setting the LCD Blink Delay
Hivac Delay 3.000s Setting for Pump n
HI VAC Sensor DELAY? NO/YES
Setting the Hi Vacuum Sensor Delay
HV Vent DLY 10.000s Setting for Pump n
HI VAC Vent DELAY? NO/YES
Setting the Hi Vacuum Vent Delay
HI VAC Load COUNT? NO/YES
Setting the Hi Vacuum Load Count
HV Load CNT
Input Monitor Screen
Using the Installation Aids Menus
Input MONITOR? NO/YES
BNK0 BNK1
Automatic or MANUAL? =AUTO Y=MANUAL
Output CONTROL? NO/YES
Output Control Menu
OUTBNK0 OUTBNK1
Other Controller Restricted Areas
OEM Menu Access Is NOW Available
OEM SETTINGS? NO/YES
Using the OEM Service Menu
PWL11111 PWL22222 PWL33333 PWL44444
Recovering Passwords
Verifying Software Checksums
Restoring the Controller to Factory Defaults
ROM Checksum
Press YES to Resume