Main Power
Your
Marked on the faceplate of the fuse holder shows the configuration for the desired voltage. Using a small screwdriver, remove the fuse holder. To select the operating voltage, align the arrow marker on the holder and the switch as shown in the following section.
The 12 station controller has a standard IEC power cord. Plug the cord into any standard 115 VAC outlet. If you selected the 220 VAC option, remove the end connector and install a standard 220 VAC plug. Doing so does NOT effect the controllers warranty.
DC Controller Power Sources
Although main controller power is 115/220 VAC, control power is actually unregulated 24 VDC. The 24 VDC control power supplies the power for all solenoids, sensors, and the controller itself. The unregulated supply can deliver up to five (5) amps of continuous current to drive a very large system.
Inputs
•Station connections
•High vacuum connections
•System error connections
Outputs
•Station connections
•Pump/blowback
•Spare
3-4 Setup
This section provides the procedures for configuring your
Configuration of your controller includes setting the number of stations and pumps, setting variables such as convey time and
Note: Before carrying out these procedures, install all equipment as described in this section and in the Mechanical Components manual.
To help you set up the controller quickly, this section walks you through the setup using the menu system. This procedure will work for most applications, but you may need to perform some minor adjustments afterwards to achieve the best conveying performance.
Note: The controller must be in Offline mode to permit access to the menu system.