IMPORTANT SAFETY
INFORMATION
WARNING: Warnings contain d irections that you must follow for your
personal safety. Follow all instructions carefully.
Please read the following safety informat ion thoroughly before
installing the PS Hub.
Installation and removal of the unit must be carried out by qualified
personnel only.
Connect the unit to an earthed power supply to ensure compliance
with European safe ty standards.
The power cord set must be approved for the country where it will
be used.
The appliance coupler, that is, the connector to the device itself and
not the wall plug, must have a configuratio n for mating with an
EN60320/IEC320 appliance inlet.
For U.S.A. and Canada:
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least 10A.
The attachment plug must be an earth-groun ding type with a
NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.
For Denmark:
The supply plug must comply with section 107- 2-D1, standard
sheet DK2-1a or DK2-5a.