IMPORTANT SAFETY
INFORMATION
WARNING: Warnings contain d irections that you must follow for your
personal safety. Follow all instructions carefully.
Please read the following safety informat ion thoroughly before
installing the PS Hub.
■Installation and removal of the unit must be carried out by qualified
personnel only.
■Connect the unit to an earthed power supply to ensure compliance
with European safe ty standards.
■The power cord set must be approved for the country where it will
be used.
■The appliance coupler, that is, the connector to the device itself and
not the wall plug, must have a configuratio n for mating with an
EN60320/IEC320 appliance inlet.
■For U.S.A. and Canada:
■The cord set must be UL-approved and CSA certified.
■The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
■The cord set must have a rated current capacity of at least 10A.
■The attachment plug must be an earth-groun ding type with a
NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V)
configuration.
■For Denmark:
■The supply plug must comply with section 107- 2-D1, standard
sheet DK2-1a or DK2-5a.