Configuring Serial Ports with DCEs

75

LH4 = 22.5 db

SH4 = 399 - 533 feet

 

SH5 = 533 - 655 feet

 

 

3Set the baud rate (56 or 64 kbps) for the DS0 channel using:

SETDefault !<path> -PATH T1DSoChnlBaud = <FT156KFT164K>

4Set the path clock using:

SETDefault !<path> clock = [Internal External]

5Re-enable the path using:

SETDefault !<path> -PATH CONTrol = Enabled

The following optional settings are also available:

T1FrameMode

Superfame (SF)

Extended Superframe (ESF)

T1LineCoding

Binary with 8 zero substitution (B8ZS)

Alternate Mark Inversion (AMI)

Alternate Mark Inversion with bit 7 zero code substitution (AMIB7ZCS)

Configuring Serial This section describes how to configure the serial ports with modems,

Ports with DCEs CSU/DSUs, or ISDN TAs attached.

Before beginning this procedure, complete the following tasks:

Cable the serial port and connect it to the telephone network.

Log on to the system with Network Manager privilege.

The serial port automatically detects the following settings:

Line type dial-up or leased

Clock — external

Connector type RS-232, V.35, X.21, RS-449, or RS-530

ISDN TAs If you are attaching an ISDN TA, you must configure the TA with the SPIDs, switch type, local telephone numbers, and Multilink PPP options

Page 75
Image 75