Shut Down, Restart Procedures

Appendix: SAN Installation

D.Plug the other end of the CAT-5E crossover cable into the storage device’s port “0” (zero) on the right (see Figure 3 Item B).

E.Plug the storage device’s AC power cords into the back of the unit (see Figure 3 Item C).

F.Plug the loose ends of the AC power cords into a power source with an appropriate rating. It is strongly suggested you use an uninterruptible power supply.

Shut Down the Storage Device UnitWARNING: Be sure all drives are installed in the storage device unit before powering on the unit. Be sure the ER unit is not powered on.

G.Turn on the power switches at the back of the storage device, which are positioned to the right of the power cord connectors.

The boot-up process may take up to 5 minutes. When the unit is booted up, the three vertical LED lights at the left of the front panel will be lit up (see Figure 4).

Once all LED lights are lit, the ER can be powered on.

Shut Down, Restart Procedures

Follow the procedures in this section if you need to shut down or restart the storage device.

Shut Down the Storage Device Unit

If you need to shut down the storage device, always follow these steps:

Figure 4: LED

display

A.Power off the ER unit first. (Refer to the Physically Connect the ER to the Network sub-step in Step 1B of the ER section for shut down procedures.)

B.Power off the storage device next by turning off both switches in the back of the unit.

Restart the Storage Device Unit

The storage device must be restarted after a power failure. In this instance, the storage device may already be turned on, but needs to be booted up again.

Restart the Storage Device UnitWARNING: You must always power on the storage device before powering on the ER unit. Since the storage device is an information database, if you experience a power interruption or if you power off the storage device without going through the standard shut down procedures, you may lose data and/or damage the file system.

To restart the storage device, press the power button on the front panel. The boot-up process may take up to 5 minutes.