Data format

S

T

,

+

0

0

0

 

0

0

.

0

0

 

 

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

 

 

 

Data

 

 

 

Unit Terminator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Separator

 

 

(“

 

” shows a space.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

‰There are four types of headers:

ST : Stable weighing data (including % data)

QT : Stable counting data

US : Unstable weighing data (including count and %)

OL : Out of weighing range (Over)

‰The data is normally 9 digits including a decimal point and a sign.

‰There are 14 types of units:

 

 

 

 

g

: Weighing data “gram”

 

 

 

 

 

 

P C

: Counting data “pcs”

 

 

 

 

 

 

 

%

: Percentage data “%”

 

 

 

 

 

o z

: Weighing data “decimal ounce”

 

 

 

 

 

 

l b

: Weighing data “decimal pound”

 

 

 

o z t

: Weighing data “troy ounce”

 

 

 

c t

: Weighing data “carat”

 

 

 

mom

: Weighing data “momme”

d w t

: Weighing data “penny weight”

 

 

GN

: Weighing data “grain”

 

 

 

 

 

 

N

: Force data “Newton”

 

 

 

 

 

 

 

t l

: Weighing data “tael”

 

 

 

 

 

 

 

t

: Weighing data “tola”

 

 

 

 

 

 

DS

: Calculated density (specific gravity) value

 

 

‰The terminator is always CRLF.

‰Example of output data:

Weighing data “gram” Counting data Percentage data

Out of range “gram” (+) Out of range “pcs” (-)

S

T

,

+

0

0

1

2

3

4

.

5

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

T

,

+

0

0

0

1

2

3

4

5

 

 

 

 

P

 

C

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

T

,

+

0

0

0

1

2

3

.

4

 

 

 

 

 

 

%

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

L

,

+

9

9

9

9

9

9

.

9

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

L

,

-

9

9

9

9

9

9

9

9

 

 

 

 

P

 

C

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data output mode

‰Stream mode

Set the function “prt 0”.

The balance outputs the current display data. The data-update rate is approximately 10 times per second. This rate is the same as the display-update.

The balance does not output data while it is in the setting mode.

24

Page 26
Image 26
A&D EJ-4100, EJ-6100, EJ-440, EJ-3000, EJ-120, EJ-2000, EJ-1500 manual Data format, Data output mode