CONFIGURATION OPTIONS

Page 5-3

3 — Line Spacing

This option allows the user to set line spacing to any value between 1 and 9. Any line feeds received from the coax host or sent out by the ULTRA are multiplied by the value of this option. The default is 1 (single spacing).

4 — Local Copy Null Line Suppression

In a local copy or DSC print job, this option determines whether or not lines containing only nulls are printed. The default value is “Yes.”

5 — Xerox 36 Hex Transparency

If this option is set to “Yes,” Xerox 36 Hex transparency is enabled. If this option is set to “No,” 36h will be ignored. The default value is “No.” Refer to Section 11 — Transparency Modes for more information.

Note: If this option is set to “Yes,” Option #1 — Column width should be set to 0 (infinite line length), Option #2 — Lines Per Page should be set to 0 (infinite page length), and Option #15 — Bold Print Emulation should be set to C (none). Otherwise, unpredictable formatting errors could occur. Refer to Section 12 — DisplayWrite 370 Support for more information.

6 — Form Feed Before Local Copy

Determines whether or not a form feed will be sent to the printer before beginning a local copy. The default value is “No.”

7 — Form Feed After Local Copy

Determines whether or not a form feed will be sent to the printer after finishing a local copy. The default value is “Yes.”

8 — New Line Order

Determines whether new lines will be sent to the printer as: (A) CR/LF (a carriage return followed by a line feed) or as (B) LF/CR. The default is (A).