FCC Statement

This equipment generates, uses and can radiate radio frequency energy. If it is not installed and used in strict accordance with AGILE’s instructions, it may cause interference to radio and television reception. This equipment has been tested and complies with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio and television reception, which can be determined by turning the equipment off, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient the receiving antenna.

Relocate the ULTRA with respect to the receiver.

Move the ULTRA away from the receiver.

Plug the ULTRA into a different outlet so that the ULTRA and receiver are on different branch circuits.

If necessary, the user should consult the dealer or an experienced radio/ television technician for additional suggestions. The booklet, How to Identify and Resolve Radio-TV Interference Problems, prepared by the Federal Communications Commission, may also be helpful. This booklet is available from the US Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.

WARNING: This equipment has been certified to comply with the limits for a Class A computing device, pursuant to Subpart J of Part 15 of FCC rules. Only peripherals (computer input/output devices, printers, plotters, etc.) certified to comply with the Class A (commercial) or Class B (residential) limits may be attached to the ULTRA. Operation with non-certified peripherals is likely to result in interference to radio and TV reception.

Note: This equipment uses shielded cables to meet compliance limits for a Class A computing device. Shielded cables must be used to ensure this equipment continues to meet these limits. The shield must be terminated to the metallic connector at both ends to guarantee adequate suppression of undesirable emissions. All cables are fully double shielded (Mylar foil and tinned copper braid.)

Page 20
Image 20
Agilent Technologies 6287 manual FCC Statement

6287 specifications

Agilent Technologies 6287 is a high-performance signal generator specifically designed for advanced electronic testing and measurement applications. Recognized for its robustness and versatility, the 6287 caters to various sectors, including telecommunications, automotive, aerospace, and semiconductor industries. One of its main features is its capability to generate a wide range of frequencies, making it ideal for comprehensive testing of components and systems.

The Agilent 6287 boasts a frequency range extending from 10 MHz to 6 GHz, which allows users to perform tests across a broad spectrum of applications, including RF and microwave devices. Its excellent output power levels provide a significant advantage when dealing with devices requiring high signal strengths for accurate testing. Additionally, the unit supports various modulation techniques, including AM, FM, PM, and pulse modulation. This versatility ensures that engineers can evaluate the performance of devices under different signal conditions, crucial for real-world applications.

Another defining characteristic of the Agilent 6287 is its exceptional phase noise performance, delivering reliable and accurate results. High-phase noise can obscure signal testing results, making the 6287's low levels a critical factor for effective device evaluation. The generator's time domain capabilities add further value, allowing engineers to analyze signals in both frequency and time domains effectively.

With a user-friendly interface, the 6287 simplifies operation while supporting a wide range of programming capabilities. This makes it easy to integrate into automated test setups or to control it via standard programming languages, enhancing flexibility for engineering teams. The device also features advanced synchronization options that facilitate multi-instrument setups, allowing seamless collaboration with other measurement tools.

The Agilent Technologies 6287 is built with robust construction and thermal management features, ensuring reliable performance in demanding environments. Its compact design enables easy installation in test racks or mobile test setups. Overall, the Agilent 6287 signal generator is a powerful tool that stands out in the field of electronic testing, efficiently meeting the evolving needs of modern engineering applications. Its mixture of frequency versatility, modulation support, excellent phase noise performance, and user-friendly operation makes it an indispensable asset for professionals working with complex signal testing scenarios.