Setting the timer [Timer setting]

Set the time for each operation.

1 Click Timer setting in the table of contents.

2 Set the time for the following operations respectively.

*The setting range is displayed on the right side of each input box.

[Call]:

Set the duration of call from door stations to [Normal], [Priority] or [Urgent].

[Communication]:

Set the duration of communication between stations in the system including between remote sites [Via IP].

*[In Local] and [Telephone]: Not available in a network direct system.

[Paging]:

Set the duration of paging.

[Monitor]:

Set the duration of monitoring only one station.

[Scan monitor: Switching]:

Set the duration of monitoring each station while scan- monitoring.

NOTE:

The actual duration slightly differs from the setting value.

[Contact output]: (Not available)

[Door release]:

Set the duration of door release.

*If you set the time to “0”, the door is released while the door release button on the master station is held down.

3 Click Temporarily stored to save the current setting results temporarily.

*If you wish to cancel the setting results you have made, click a title in the table of contents or “Refresh” in the web browser menu.