Setting stations to receive calls and zones to receive paging from remote sites [Remote site pilot call setting]

Set the master stations and sub stations to receive calls, and zones to receive paging from remote sites.

*The setting can be made for each priority individually.

1 Click Remote site pilot call setting in the table of

contents.

2 Make the setting by clicking

Advanced settings

for

 

the setting items G , H , I

respectively to open the

 

corresponding window.

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

*1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

 

 

 

 

*2

 

 

 

 

 

 

 

 

 

3 Make the setting in the displayed window(s).

See the detailed instructions for G , H , I on the right column of this page.

4 After the setting is finished on the corresponding window, click Close to close the window.

5 Click Temporarily stored to save the current setting results temporarily.

*If you wish to cancel the setting results you have made, click a title in the table of contents or “Refresh” in the web browser menu.

*1: The settings on this item are available for a call from the standard (IP) system in a remote site. The setting method is the same as the item H . (Refer to the “SETTING MANUAL”

for a standard (IP) system for details.)

*2: Not available

GSettings on [Remote site master call] setting window

You can set a station (master station or door station) that receives a call from a master station in a remote site. One station can be set for each priority.

1)Click Reference for “Normal”.

All the registered stations are displayed in the list in another window.

2)Check the box for the target station in the list, and then click Close .

The current window closes and the set station is displayed in the [Remote site master call] setting window.

To delete a set station

Click Delete for "Normal".

*Selecting another station also overwrites the previous one.

Make the setting for “Priority” and “Urgent” in the same way.

HSettings on [Remote site door call] setting window

You can set up to 20 master stations that receive a call from a door station in a remote site. Up to 20 master stations can be set for each priority.

1)Click Reference for “Normal”.

All the registered master stations are displayed in the list in another window.

2)Check the boxes for the target master stations in the list, and then click Close .

The current window closes and the set stations are displayed in the [Remote site door call] setting window.

To delete a set station

Check the box for the target station and click Delete .

*You can also select two or more stations and delete them at a time.

Make the setting for “Priority” and “Urgent” in the same way.

ISettings on [Remote site paging] setting window

You can set a zone that receives paging from a remote site. One zone can be set for each priority.

1)Select the target zone from the pull-down menu for “Normal”.

*Make the setting for “Priority”,“Urgent”and “Broadcast” in the same way.

26

Page 26
Image 26