Preliminary Information
IR Communications Menu
PHM1003R
Figure 3
The IR Communications Menu displays while the control is communicating with a PDA. The control will jump back to the previous page when the communication is complete.
IR Communications Error Menu
Invalid Data
PHM1004N
Figure 4
The IR Communications Error Menu displays after the control had an error communicating with a PDA. The control will return to previous page after 3 seconds.
Restore to Factory Defaults
When the user selects Restore All Cycles And Global Settings To
Default Washer-Extractor Settings
Language = English Maximum Balance Retries = 3 Water Reuse = Disabled Rapid Advance = Enabled Water Recirculation = Disabled External Dispenser Pause = Disabled Shakeout = 40 seconds
Banner # 1 = Blank
Banner # 2 = Blank Daylight Saving = Enabled Water Levels
High = 27 Medium = 15 Low = 3
Water Temperature
Hot = 140 F
Warm = 100 F
Cold = 35 F Cooldown = 110 F
Temperature Controlled Fill = Disabled Audio Signal External Signal = Disabled Keypad Signal (beep) = Enabled
End of Cycle / Segment Sound = Enabled Low, 5 second duration
Alarms
Fill = 5 minutes Drain = 2 minutes Heat = 1 hour 30 minutes
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138801 |