Preliminary Information

IR Communications Menu

PHM1003R

Figure 3

The IR Communications Menu displays while the control is communicating with a PDA. The control will jump back to the previous page when the communication is complete.

IR Communications Error Menu

Invalid Data

PHM1004N

Figure 4

The IR Communications Error Menu displays after the control had an error communicating with a PDA. The control will return to previous page after 3 seconds.

Restore to Factory Defaults

When the user selects Restore All Cycles And Global Settings To Factory-Defaults, the control resets all of the default values. The control also resets Machine Cycles #1 through #41. The control will also reset the following to factory-defaults:

Default Washer-Extractor Settings

Language = English Maximum Balance Retries = 3 Water Reuse = Disabled Rapid Advance = Enabled Water Recirculation = Disabled External Dispenser Pause = Disabled Shakeout = 40 seconds

Banner # 1 = Blank

Banner # 2 = Blank Daylight Saving = Enabled Water Levels

High = 27 Medium = 15 Low = 3

Water Temperature

Hot = 140 F

Warm = 100 F

Cold = 35 F Cooldown = 110 F

Temperature Controlled Fill = Disabled Audio Signal External Signal = Disabled Keypad Signal (beep) = Enabled

End of Cycle / Segment Sound = Enabled Low, 5 second duration

Alarms

Fill = 5 minutes Drain = 2 minutes Heat = 1 hour 30 minutes

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138801