Diagnostic
Inputs Outputs Menu
Outputs:
S1 | S2 | S3 |
| S4 | AX1 | HF | CF | FW | RV |
SP1 | ON | HT RUN REV SPD1 SPD2 SPD3 | |||||||
HS | CS | RFA | RFB | RDB | AX3 | AX5 | DR | AX4 | |
AX2 | ES1 ES2 | ES3 | ES4 | ES5 | ES6 | ES7 | ES8 |
Inputs: |
|
DR BAL PAUS DFLT FSW WL | RS TS DL |
OSW PSW |
|
Inputs Outputs | RUNNING |
| PHM1059R |
Figure 65 |
|
When the Inputs Outputs Menu is accessed through the Diagnostic Menu, the user can change outputs. The Close Door Menu will come up if the door is not closed. The user can scroll through the outputs using any of the arrow keys, the cursor is indicated by flashing the active output on the screen. The user must
“setup” the outputs to be turned on. The keypad is used to toggle individual outputs to be turned on or
off. After the keypad is pressed the control will
turn the selected outputs on and display the text “RUNNING”. The outputs cannot be toggled until
the keypad is pressed. The text “RUNNING” is
no longer displayed. The screen will still show the selected outputs on the screen and the user can again
toggle outputs to be turned on or off. If the
keypad is pressed at any time during this test, the control will turn off all outputs if the test is running or return to the previous screen if the test is not running.
52 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138801 |