Global Setup

Alarms Program Menu

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

ss

 

 

 

 

 

 

:

 

 

 

 

Fill

 

5

 

00

 

 

 

 

 

 

 

 

 

 

Drain

 

2

 

:

00

 

 

 

 

 

h

 

mm

 

 

 

 

 

 

 

 

 

Heat

1

 

:

30

 

 

 

 

 

 

 

 

 

 

 

 

Alarms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHM1044R

 

 

 

 

 

 

 

 

 

 

 

Figure 50

 

 

 

 

The Alarms Program Menu is used to set the fill, drain, and heat alarm times.

The and keypads are used to move the

highlighted box through the different items in the Alarm Program Menu. Once the item is highlighted,

the value can be changed by using the

and keypads. Pressing the or keypad will jump to the Save Changes Menu.

Use or to move highlighted box to “Yes”

or “No”. Press the keypad to return to Global Setup menu. If no changes were made, press the

or keypad to return to Global Setup Menu.

Rapid Advance Menu

Enable the Rapid Advance

Feature During Cycle Operation?

Yes No

Rapid Advance

PHM1045R

Figure 51

The Rapid Advance Menu has the option of whether the user will be able to rapid advance through steps

while the machine is operating. Press the

or keypad to change the selection. All the keypads have the same effect and will toggle the

selection between on or off. Press the or keypad to jump to the Save Changes Menu. Use

or to move highlighted box to “Yes” or “No”.

Press keypad to return to Global Setup Menu. If

no changes were made, press the or keypad to return to Global Setup Menu.

If the Rapid Advance Option is enabled (refer to Global Setup, Rapid Advance section), the user can advance a running machine cycle with presses of

the keypad. When the keypad is pressed,

the control will immediately show the next cycle step in the Run Menu but will not change the outputs for a period of at least five (5) seconds. The user may advance into any cycle step except the Spray Rinse Extract and Extract Steps. If the control is executing a

Drain step and the user presses to execute a

Rapid Advance, the control will skip over the Extract Step. When the cycle is completed, the audit counter, Total Rapid Advance Cycles is incremented rather than the Total Machine Cycles audit counter. In addition this cycle is recorded in the audit list “Last 25 Machine Cycles Completed” and the audit list “Last 10 Machine Cycles Rapid Advanced/Aborted.” Refer to UniLinc PC and PDA Application User Instructions for additional information on using a PDA.

In the Run Menu, the total remaining cycle time is reduced by the corresponding advance step time if programmed. If the Rapid Advance Option is disabled preventing a manual Rapid Advance, the user may still execute a Rapid Advance using the PDA.

44

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138801