Drive Fault Error

If the control detects the VFD Fault Switch input as open, the control will log a Drive Fault error and increment the Drive Fault Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “Drive Fault” on the Alarms (2 of 4) Menu for the total error count.

Fill Alarm Error

When the Fill Alarm time is exceeded, the control will stop the cycle and display the Cycle Stopped Error Menu and count and store the Total Fill Errors audit counter. The control saves the error type, cycle, segment and step in which it happened, the date and the time on the Alarms (1 of 4) Menu. View “Fill” on the Alarms (2 of 4) Menu for the total error count. The audio signal will also be turned on for the error condition. The Cycle Stopped Error Menu is displayed alternating with the Run Menu (3 seconds Error Menu/ 3 seconds Run Menu) with the Alarm on until the appropriate user input occurs. The user is given the option of continuing or stopping the machine cycle.

Frame Balance Switch Error

If the control detects a Frame Balance Switch error during a cycle, the control will abort the machine cycle, display the Cycle Aborted Error Menu and count and record the Frame Balance Switch Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “Frame Balance” on the Alarms (2 of 4) Menu for the total error count. The audio signal will also be turned on for the error condition. The Cycle Aborted Error Menu is displayed with the Alarm on until the appropriate user input occurs. The machine cycle is aborted and the user is only given the option of powering down the machine to service the Frame Balance Switch error condition.

Open Temperature Sensor Error

If the control senses a temperature less than 5 F in a machine equipped with a temperature sensor, the control will abort the machine cycle, display the Cycle Aborted Error Menu and record and count the Open Thermistor Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “Open” on the Alarms (2 of 4) Menu for the total error count. The audio signal will also be turned on for the error condition. The Cycle Aborted Error Menu is displayed with the Alarm on until the appropriate user input occurs. The machine

Machine Identification

cycle is aborted and the user is only given the option of clearing the Cycle Aborted Error Menu and returning to the Cycle Menu.

Rotation Sensor Error

If the control senses an invalid signal from the Rotation Sensor, the control will continue normal machine operation as if it had no Rotation Sensor (load Coast Times), and count and record the Rotation Sensor Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “Rotation” on the Alarms (3 of 4) Menu for the total error count. The machine cycle will continue with coast times loaded where rotation detection is required. It will operate this way until any loaded coast time has been allowed to expire and the machine power has been reset. When power is reset, the machine will acknowledge that it has a rotation sensor equipped and return to normal operation.

Shorted Temperature Sensor Error

If the control senses a temperature greater than 220 F in a machine equipped with a temperature sensor, the control will abort the machine cycle, display the Cycle Aborted Error Menu and increment the Shorted Thermistor Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “Short” on the Alarms (3 of 4) Menu for the total error count. The audio signal will also be turned on for the error condition. The Cycle Aborted Error Menu is displayed with the Alarm on until the appropriate user input occurs. The machine cycle is aborted and the user is only given the option of clearing the Cycle Aborted Error Menu and returning to the Cycle Menu.

SPI Error

If the control is unable to communicate with the Output Board the control will abort the machine cycle, display the Cycle Aborted Error Menu and increment the SPI Errors audit counter. The control saves the error type, cycle, segment and step in which it happened and the date and the time on the Alarms (1 of 4) Menu. View “SPI” on the Alarms (3 of 4) Menu for the total error count. The audio signal will also be turned on for the error condition. The Cycle Aborted Error Menu is displayed with the Alarm on until the appropriate user input occurs. The machine cycle is aborted and the user is only given the option of clearing the Cycle Aborted Error Menu and returning to the Cycle Menu.

F8138801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

57