Program Menu

The and keypads are used to move the cursor to the different parameters and Internal

Supplies 1 through 5. The and keypads are used to move the cursor to the External Supplies 1 through 8. Once a supply has been chosen, it is

selected by pressing the keypad. The supply is activated if it is highlighted. The time can be edited for each supply step by moving the highlighter box to

time. Press . Blinking underline indicates the number is ready to be changed.

Pressing the keypad will jump to the Save Changes Menu.

Agitate Step Menu

Cycle01: Towels White Bleach

Segment01: Prewash

Agitate:

Type

Recirc

Speed Time

No Rotation

Off

Reduced

Drain Only

On

Normal

3F/27P/3R

 

 

4F/56P/4R

 

 

10F/20P/10R

 

 

18F/3P/18R

 

m m : s s

Continuous

 

 

 

Modify Cycle

 

 

 

 

PHM1029R

Figure 32

The purpose of the Agitate Step Menu is to program the parameters used while the machine is performing the Agitate Step. The Agitate cycle step can be turned on or off. The type of agitation is the first available parameter. The agitation type parameter menu has seven (7) choices with 18F/3P/18R (18 seconds forward, 3 seconds pause, and 18 seconds reverse) being the default.

The recirculation parameter controls the operation of the recirculation pump during machine operation. The user can either turn it on or off. If the water recirculation option is not enabled in Global Setup parameter, then this parameter will not display. The Wash speed can be programmed to either Normal Wash speed or Reduced Wash speed.

The Agitate step can be programmed to a time from one (1) minute to 30 minutes.

NOTE: If the Agitate type is programmed to a value of “No Rotation”, the cycle step time can be programmed to a value from one (1) minute to 24 hours.

Pressing the keypad will jump to the Save Changes Menu.

Cool Down Step Menu

Cycle01: Towels White Bleach

Segment01: Prewash

Cooldown:

Temp

GLOBAL

Modify Cycle

PHM1030R

Figure 33

The Cool Down Step Menu gives the user the option to set the Cool Down Option after the Agitation Step. The Cool Down cycle step can be turned on or off. If turned off, the control will advance to the next cycle step (Drain).

The temperature setting allows the user to set the Cool Down temperature of the water after the Agitation Step has ended. The temperature will default to cool down temperature set in Global Setup. To change cool

down temperature, press the and keypads.

Press the keypad to jump to the Save Changes Menu.

36

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138801