Program Menu
The and
keypads are used to move the cursor to the different parameters and Internal
Supplies 1 through 5. The and
keypads are used to move the cursor to the External Supplies 1 through 8. Once a supply has been chosen, it is
selected by pressing the keypad. The supply is activated if it is highlighted. The time can be edited for each supply step by moving the highlighter box to
time. Press . Blinking underline indicates the number is ready to be changed.
Pressing the keypad will jump to the Save Changes Menu.
Agitate Step Menu
Cycle01: Towels White Bleach
Segment01: Prewash
Agitate:
Type | Recirc | Speed Time |
No Rotation | Off | Reduced |
Drain Only | On | Normal |
3F/27P/3R |
|
|
4F/56P/4R |
|
|
10F/20P/10R |
|
|
18F/3P/18R |
| m m : s s |
Continuous |
| |
|
| |
Modify Cycle |
|
|
|
| PHM1029R |
Figure 32
The purpose of the Agitate Step Menu is to program the parameters used while the machine is performing the Agitate Step. The Agitate cycle step can be turned on or off. The type of agitation is the first available parameter. The agitation type parameter menu has seven (7) choices with 18F/3P/18R (18 seconds forward, 3 seconds pause, and 18 seconds reverse) being the default.
The recirculation parameter controls the operation of the recirculation pump during machine operation. The user can either turn it on or off. If the water recirculation option is not enabled in Global Setup parameter, then this parameter will not display. The Wash speed can be programmed to either Normal Wash speed or Reduced Wash speed.
The Agitate step can be programmed to a time from one (1) minute to 30 minutes.
NOTE: If the Agitate type is programmed to a value of “No Rotation”, the cycle step time can be programmed to a value from one (1) minute to 24 hours.
Pressing the keypad will jump to the Save Changes Menu.
Cool Down Step Menu
Cycle01: Towels White Bleach
Segment01: Prewash
Cooldown:
Temp
GLOBAL
Modify Cycle
PHM1030R
Figure 33
The Cool Down Step Menu gives the user the option to set the Cool Down Option after the Agitation Step. The Cool Down cycle step can be turned on or off. If turned off, the control will advance to the next cycle step (Drain).
The temperature setting allows the user to set the Cool Down temperature of the water after the Agitation Step has ended. The temperature will default to cool down temperature set in Global Setup. To change cool
down temperature, press the and
keypads.
Press the keypad to jump to the Save Changes Menu.
36 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138801 |