Global Setup
Water Management Menu
|
|
|
|
|
|
| Does the Machine Have |
|
|
| |
| No |
|
| ||
| Water Reuse Installed? |
|
| ||
|
|
|
| ||
| Does the Machine Have |
|
|
| |
| No |
|
| ||
| Water Reuse Installed? |
|
| ||
|
|
|
|
|
|
| External Dispenser Pause | Off |
|
| |
|
|
|
|
| |
|
|
|
|
|
|
| Water Mgmt. (1 of 4) |
|
|
|
|
|
|
|
|
|
|
|
|
| PHM1273R | ||
|
|
|
|
|
|
| Figure 46 |
|
|
|
The Water Management 1 Menu allows the user to set the water reuse and water recirculation options to Yes or No. If water reuse option is turned off, the Reuse Fill Menu will not be displayed during programming
of a Segment. Press the and keypads to move the highlighted box through the different items
in the Water Management 1 Menu. Press the
or keypad to change selections to “Yes” or “No”.
The user can set the External Dispenser Pause On or Off. The control default for this option is “Off”. If programmed on, the control will wait with a normally open contact for contact closure to indicate the need for a pause in cycle operation.
Press the or keypad to jump to the Save
Changes Menu. Use or to move highlighted box to “Yes” or “No”.
Press the keypad to return to Global Setup
Menu. If no changes were made, press or keypad to return to Global Setup menu.
To view Water Management 2 Menu, press keypad while the “External Dispenser Pause” textbox is highlighted/
To view Water Management 4 Menu, press keypad while the “Does the Machine Have Water Reuse Installed?” textbox is highlighted.
Water Leak Detection |
|
|
|
|
| On |
|
| |
During Machine Cycle |
|
|
| |
|
|
|
| |
|
|
|
|
|
Number of Cycles Between | 0 |
|
| |
Day(s) Occurring |
|
|
|
|
S M T W R F S |
| |||
|
|
|
|
|
Water Mgmt. (2 of 4) |
|
|
|
|
|
|
|
|
|
|
| PHM1274R |
Figure 47
The Water Management 2 Menu allows the user to enable or disable the Water Leak Detection During Machine Cycle parameter. Once Water Leak Detection is enabled, the Number of Cycles Between and the Day(s) Occurring parameters can be changed.
Press the and keypads to move the highlighted box through the parameters of the Water
Management 2 Menu. Press the or
keypads to change the Water Leak Detection During a Machine Cycle and Number of Cycles Between
parameters’ values. Press the keypad to change the Day(s) Occurring parameter’s values.
Press the or keypad to jump to the Save
Change Menu. Use or to move highlighted box to “Yes” or “No”.
Press the to return to Global Setup Menu. If no
changes were made, press or keypad to return to Global Setup menu.
To view Water Management 3 Menu, press keypad until the menu is displayed.
To view Water Management 1 Menu, press
keypad while Water Leak Detection During Machine Cycle textbox is highlighted.
42 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138801 |