Program Menu
To set parameters in the step menus, move highlight
box to desired step parameter and press ,
the and
keypads to change values. In menus that do not have many values or items to choose from the vertical arrow keypads will toggle.
NOTE: To change a value, press the or
keypad every time a different item is to be selected.
In menus that have many values or items, the user will
be able to either toggle or slew the or
keypad. Slewing the keypads is when the user holds down a keypad for a specified amount of time and the value automatically scrolls through the parameter being modified. The slewing is based on how much time the user holds down the keypad. If the keypad is held down for longer than 2 seconds the value will begin to scroll.
During the programming of a step, if the keypad is pressed, the display will jump to the Save Changes Menu.
Reuse Fill Step Menu
Cycle01: Towels White Bleach
Segment01: Prewash
Reuse Fill:
Level |
| Valve |
|
|
|
High | Reuse A | |
|
| Reuse B |
|
| Aux Fill |
Modify Cycle
PHM1025R
Figure 28
The Reuse Fill Step Menu is used to program the Reuse Fill step while modifying the Cycle. The Reuse Fill Step can only be viewed if the Water Reuse Parameter is turned on (refer to Global Setup Water Management section), and the fill step for the segment is turned off otherwise this step is skipped and not shown. The time for this step is fixed at 5 minutes. The Fill Alarm is not active for this step. However, the control will energize cold fill and spray after five minutes until the water level reaches the programmed level.
The first programmable parameter of the Reuse Fill step is the water level. The target water level is either the programmed global value (High, Medium or Low) or a specific water level value. Global water level values are set in the Water Level Menu (refer to Global Setup, Water Level). For the specific water level value,
using the and
keypads.
The parameter after water level is valve selectors. Reuse Fill A, Reuse Fill B, or both may be activated during the Reuse Fill step. The valve can be selected
and deselected by pressing the |
| keypad. If Reuse |
|
Fill A and Reuse Fill B are deactivated, Aux Fill will activate by default. If Water Reuse is enabled, the Aux Fill will be on by default.
Press the keypad to return to Save Changes Menu.
Fill Step Menu
Cycle01: Towels White Bleach
Segment01: Prewash
Fill:
Temp | Level | Heat | Time | ||
|
|
| Low |
|
|
115 F | No Heat |
| |||
|
|
|
| To Target |
|
|
|
|
|
| |
|
|
|
| Maintain |
|
m m : s s
Modify Cycle
PHM1026R
Figure 29
The Fill Step Menu is used to program the fill step. The Fill Step contains the parameters the machine will use when it fills.
Water temperature can be either a global value or a specific temperature. The global settings are Cold (COLD), Warm (WARM), or Hot (HOT). The values for these global settings are set in the Global Setup Temperature Menu. The specific temperature selection can either be in Celsius or Fahrenheit depending on which is chosen in the Global Setup.
The water level can be set to a global value, a specific level from 1 to 30, or to overflow (OVFL). The global settings are Low (LOW), Medium (MED), or High (HIGH).
34 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138801 |