Allied Telesis x600-24Ts/XP, x600-48Ts manual Event on Master Node Reaction on Reaction on Stack

Models: x600-48Ts X600-48TS/XP X600-24TS-POE+ X600-24TS x600-24Ts/XP x600-24Ts-POE

1 112
Download 112 pages 51.04 Kb
Page 55
Image 55

x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

Table 10. State Change Table

Event on Master Node

Reaction on

Reaction on Stack

Reaction on Stack

Master

Member

Member

 

 

 

 

 

 

 

With Resiliency Link

Without Resiliency Link

 

 

 

 

Both stack links removed

No change

Fallback action1

Re-elect master 2

XEM-STK Removed or Faulty

No change

Fallback action1

Re-elect master 2

Hardware reset (or fault)

Reset / offline

Re-elect master

Re-elect master 2

Run the NO STACK ENABLE

No change

Fallback action1

Not allowed

command3

 

 

Displays Error Message

Software application problem

Reboot as stack

Re-elect master

Re-elect master

(lock-up or continual crashes)

member

 

 

 

 

 

 

Software crash or lock-up

Frozen4

Re-elect master

Re-elect master

Power-down or PSU failure

Powered down

Re-elect master

Re-elect master

 

 

 

 

Event on Stack Member

Reaction on

Reaction on Stack

Reaction on Stack

Node

Master

Member

Member

 

 

 

 

Both stack links removed

No change

Fallback action1

Re-elect master 2

XEM-STK removed or faulty

No change

Fallback action1

Re-elect master 2

Hardware reset (or fault)

No change

Reset/offline

Reset/offline

 

 

 

 

Run the NO STACK ENABLE

No change

Fallback action1

Fallback action1

command3

 

 

 

Software application failover

No change

Re-boot as slave

Reboot as stack member

(lock-up or continual crashes)

 

 

 

 

 

 

 

software crash or lock-up

No change

Frozen4

Frozen4

Power-down / PSU failure

No change

Powered Down

Powered down

 

 

 

 

1.The fallback action on a slave is first to run the fallback config script. Where there is no fallback script, the switch will disable all its switch ports.

2.The stack member assumes the role of stack master. In specific situations, this condition could result in a stack containing two masters. This would present problems with network management and the control of links that were previously aggregated.

3.The following situation will apply to a switch that has been removed from the stack by the using the

NO STACK ENABLE command:

The switch will be unaware of further faults within the stack it of which it was previously a mem- ber.

If this switch is powered cycled, all links previously shutdown will remain down as a result of running the NO STACK ENABLE command”.

4.If the slave’s ports are still up, this may cause downstream switches with trunked ports to operate incorrectly.