I n s t a l l a tio n
air supply
AIR SUPPLY
Installation of this appliance must include a provision for an adequate flow of fresh air for gas combustion. This requirement must be observed by the installer as well as the operator. The rear of the appliance provides air supply access for gas combustion and must be kept clear at all times
c a U t I o n
|
| MAkE CERTAIN ThE AREA AROuND |
|
| ThE REAR OF ThE ApplIANCE IS |
|
| kEpT ClEAR OF OBSTRuCTIONS TO |
|
| AllOW A CONTINuOuS Supply OF |
. | FRESh AIR FOR GAS COMBuSTION. | |
|
|
|
Make certain the installation maintains adequate air ventilation to provide cooling for electrical and gas components. The area around the appliance should be clear of any obstructions which might retard the flow of cooling air. Failure to observe this caution may result in damage to the control components and will void the warranty.
Local and the National Fuel Gas Code provide rules for determining the amount of fresh air necessary for combustion and ventilation of commercial cooking appliances. The codes will help determine if additional outside air may be necessary to meet health and safety regulations.
AIR ADJUSTMENTS
The appliance can be field converted from one type of gas to another (natural gas to propane or vice versa).
Optional Conversion Kits
Natural Gas to Propane | 5008903 |
Propane to Natural Gas | 5008904 |
After taking the necessary safeguards for the gas circuit by employing the
Replace orifices as shown in chart.
Replace valves located under access panel.
Set manifold pressure as shown in chart.
If any gas fittings are loose or have been replaced, perform the following test:
qUse a soap and water solution to check all fittings for leaks. Brush solution on all joints or areas where a leak may be present. If bubbles appear,
Always reconnect the gas line and inspect for leaks before replacing access panels.
c a U t I o n
DO NOT uSE CIRCulATING FANS
ON ThE FlOOR. FlOOR FANS WIll
AFFECT BuRNER OpERATION.
c a U t I o n
CONvERSIONS MuST BEpERFORMED By A CERTIFIED
SERvICE TEChNICIAN QuAlIFIED TOWORk ON GAS ApplIANCES.
| NATURAL | PROpANE | |
|
|
| |
Top Orifice | |||
# 29 | # 43 | ||
| |||
Middle Orifice | |||
# 20 | # 41 | ||
| |||
Bottom Orifice | |||
# 1 | # 38 | ||
| |||
Manifold Pressure | 5.0 µ/wc | 10.0 µ/wc | |
|
|
|