Alto-Shaam AR-6G maintenance, Cleaning & reseasoning cast iron tiles, c h a ng ing of light bulbs

Models: AR-6G

1 34
Download 34 pages 12.17 Kb
Page 22
Image 22
Cleaning & reseasoning cast iron tiles

care and cleaning

maintenance DanGer

DIsconnect UnIt from poWer soUrce before cleanInG or serVIcInG.

caUtIon

THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

Cleaning & reseasoning cast iron tiles

1.Turn the burners OFF, disconnect unit from power source and allow the appliance to cool.

2.Using hand protection, remove all cast iron tiles.

3.Using a wire brush clean off any extra food debris.

NOTE: DO NOT soak tiles in water or use soap. This may cause rusting to occur.

4.Spray each tile with cooking spray to preseason.

5.Replace the cast iron tiles.

6.Turn the units power back on and start the burners.

7.Run through a normal cooking cycle.

8.Repeat steps 1-7 as necessary.

maintenance

c h a ng ing of light bulbs

The gas appliance is furnished with three 20 watt halogen bulbs. These bulbs should be replaced with the exact duplicate or a factory recommended replacement. The logo area is furnished with three 120 volt, 60 watt bulbs.

c a U t I o n

DO NOT hANDlE NEW BulB WITh

BARE hANDS. WhITE COTTON
GlOvES ShOulD BE WORN WhEN

REplACING BulBS.

OPENING MACHINE COMPARTMENTS

Prior to opening the various sections, disconnect the electrical supply and close the gas valve located on the rear of the appliance.

The electric motor compartment is located at the left and the gas burner controls at the right of the appliance. The gas valves and intake manifold assembly along with various electrical switches are located behind the control access panel. These compartments allow access for the repair of various components of the electrical and gas circuits.

Left and Right Access Panels

Using a screwdriver, remove the various screws holding the required outside panel and remove the panel.

When the repair has been completed, the panel must be remounted and the screws tightened.

Control Access Panel

(For access to control panel components)

Remove drip tray assembly.

Remove bolts that secure access panel.

Remove access panel.

When the repair has been completed, perform the above described operation in reverse. Seal the cover in place with an approved silicone sealant (see page 14).

Rear Access Panel

(For access to electrical components)

Remove 2 screws from rear access panel.

Tip access panel back.

AR-6G Rotisserie Operation & Care Manual • 20

Page 22
Image 22
Alto-Shaam AR-6G maintenance, Cleaning & reseasoning cast iron tiles, c h a ng ing of light bulbs, DanGer, c a U t I o n