Alto-Shaam AR-6G leak testing, gas exhaust, neVer Use an open flame to leaK test, ignition system

Models: AR-6G

1 34
Download 34 pages 12.17 Kb
Page 16
Image 16
leak testing

I n s t a l l a tio n

leak testing

If a pressure leak test above 1/2 psi is to be conducted on the building supply gas piping, the shutoff gas valve and appliance inlet gas supply line must be disconnected from the building supply piping before conducting the pressure test. Failure to do so may result in damage to the manual gas valve and/or gas components in the appliance.

If any gas leak tests are to be conducted at pressures equal to or below 1/2 psi, the manual gas shut off valve upstream of the appliance must be turned off before conducting the tests.

Leak testing of the internal appliance piping system was conducted before shipping the appliance from the factory. If additional testing is needed, it should only be conducted at normal gas supply pressures. If the testing is performed using combustible gas in the piping, leak testing should be done with a soap solution (bubble checking) or other approved liquid.

The use of an electronic combustible gas leak detector is

gas exhaust

The appliance is not to be directly connected to a chimney vent system nor directly connected to a horizontal exhaust system. The unit must be installed under a ventilation hood listed as ANSI/UL 705 (latest edition), and the installation must be conducted in accordance with the ANSI/NFPA 96- 1987, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations.

Operators of the appliance should be instructed not to place any material on top of the appliance that would

obstruct the flow of flue products from the opening. Operators should also be instructed that flue gases are hot

and any material or items placed on top or in front of the

flue defector could be damaged or cause a fire hazard.

helpful; however, this type of detector can be oversensitive. Electronic detectors may indicate false leaks from other sources which would not be detected when checking with a liquid solution to verify a no-hazard gas connection.

When starting the appliance after initial installation, the gas lines must be free of air which may take up to 30 minutes to purge from supply line. If the burners do not light after this period of time, call factory for assistance.

gas exhaust DanGer

neVer Use an open flame to leaK test.

D a n G e r

before startInG the applIance, maKe certaIn yoU Do not Detect the oDor of Gas.

IF THE ODOR OF GAS IS DETECTED:

DO NOT attempt to light any appliance.

DO NOT touch any electrical switches.

Extinguish any open flame.

Use a telephone OUTSIDE THE PROPERTY & IMMEDIATELY contact your gas supplier.

If unable to contact your gas supplier, contact the fire department.

ignition system

This unit is equipped with "direct spark ignition" for ease of lighting the burners.

The electrodes are located just above the burner under the burner cover on the right hand side of the appliance. These electrodes are very fragile and care must be taken if adjustment is required. Special care must be used to prevent breakage of the porcelain insulator.

If the porcelain is damaged or broken, the igniter assembly must be replaced. The end of the electrode must have a gap of 1/8" to 3/16" (3mm to 5mm) from the top surface of the burner. The spark must be maintained between the electrode and the burner for proper ignition.

AR-6G Rotisserie Operation & Care Manual • 14