aThe MAIN POWER switch is located on the left side of the control panel.

bThe LIGHT SWITCH controls cook cavity and Rotisserie logo light.

cBURNER CONTROL AND CONTROL BURNER FLAME HEIGHT is used to activate burner ignition modules and adjust flame height.

dSpit Rotation switches are labeled TOP, MIDDLE, and BOTTOM. When in the ON position, each switch will activate the corresponding double set of spits for each switch.

eEMERGENCY STOP is located in the center of the control panel which shuts down the system in an emergency.

fCOOK TIMER (2 hour maximum)

 

 

 

g a s

 

n a t u r a l

 

 

p r og paas n e   

TO LIGHT THE BURNERS:

1.Select corresponding gas valve knob. Rotate the knob to the ignite position. (H=High)

2.If the burner fails to ignite after 5-seconds, turn valve to the OFF position. Open the doors to allow the gas to dissipate and repeat the ignition process.

3.After burner has ignited, rotate the gas valve to flame height desired for cooking.

TO SHUT OFF BURNERS:

Rotate the gas valve knob to the OFF position.

RECOMMENDED LIGHTING SEQUENCE

Natural Gas: TOP MIDDLE BOTTOM

Propane Gas: BOTTOM MIDDLE TOP