Alto-Shaam AR-6G Positioning Requirements, I n s t a l l a tio n, site INSTALLATION, 457mm, 102mm

Models: AR-6G

1 34
Download 34 pages 12.17 Kb
Page 9
Image 9
POSITIONING REQUIREMENTS

site INSTALLATION

POSITIONING REQUIREMENTS

qIn order to ensure proper ventilation, a minimum distance of at least 18" (457mm) must be kept from the side panels (left and right) of the appliance and any adjoining surfaces.

NOTE: If adequate service clearance is not provided, it will be necessary to disconnect the gas connection to move the appliance. Charges in connection with inadequate service access are not covered under warranty.

qAllow a minimum clearance of 4" (102mm) from the back of the appliance for gas plumbing connections.

20"

(508mm)

77-1/2" (1969mm)

18" (457mm) 20"(457mm)

79" (1999mm)

I n s t a l l a tio n

qAllow a 20" (500mm) clearance at the top of the appliance for free air movement and for the vent(s) located at the top.

qDo not install the appliance adjacent to heat producing equipment such as fryers, broilers, etc. Heat from such appliances may cause damage to the Electrical Components of the appliance. Minimum clearance recommended: 20" (500mm)

Place the appliance on a stable, noncombustible level horizontal surface. Level the appliance front-to-back and side-to-side by means of the adjustable casters.

qRear of unit should be slightly elevated via caster adjustment to allow the doors to remain open while operator is working in the unit.

18"

4"

4"

(457mm)

(102mm)

 

 

45" (1140mm)

 

 

 

(102mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR-6G Rotisserie Operation & Care Manual • 7

Page 9
Image 9
Alto-Shaam AR-6G manual Positioning Requirements, I n s t a l l a tio n, site INSTALLATION, 457mm, 102mm, 45 1140mm