s e rv ic e
t r oub l e s h o o ting guide
DEFECT OBSERVED | POSSIBLE CAUSE | REMEDY | |
|
|
| |
| ELECTRICAL |
| |
|
|
| |
Spits and lamps do not work | No power supply to unit. | Verify unit has power to it. | |
Reset circuit breaker. | |||
|
| ||
Interior light off but spits work | Defective bulb. | Replace bulb. | |
|
|
| |
One spit is not turning | Defective motor. | Contact manufacturer | |
for replacement. | |||
|
| ||
One or all spits not turning | Defective switch or | Contact manufacturer | |
power supply. | for replacement. | ||
| |||
| GAS CIRCUIT |
| |
|
|
| |
| Gas shutoff is in OFF position. | Check main supply. | |
| Open closed valve. | ||
None of the burners are lighting | Flexible gas line not connected. | ||
Reconnect gas line. | |||
| Safety switch is not working. | ||
| Reset safety switch. | ||
|
| ||
|
|
| |
One burner heats irregularly | Burner orifices are clogged. | Clean or replace. | |
or not at all | Inlet pressure too low. | Contact qualified gas specialist. | |
|
|
|
of