Andrew 9.3-Meter ESA manual Grounding Cable Attachment Step, Installation Procedures

Models: 9.3-Meter ESA

1 66
Download 66 pages 32.87 Kb
Page 27
Image 27
Grounding Cable Attachment

Grounding Cable Attachment

Step 1

Note: Thoroughly clean exposed portions of grounding cables, unplated portion of uni- versal terminals and corresponding mounting surfaces using a wire brush. Liberally apply supplied 203233-2 conductive grease to all connection surfaces prior to and after instal- lation. Thoroughly remove conductive grease from hands and tools using soap and water.

Refer to Figure 22. Remove existing 7/8 by 2-1/4 in (57 mm) hardware at indicated posi- tions and install grounding cables as shown.

Use supplied 7/8 by 2-3/4 in (70 mm) hardware

Figure 22

27

Installation Procedures

Page 27
Image 27
Andrew 9.3-Meter ESA manual Grounding Cable Attachment Step, Installation Procedures