Section 10–Part Numbering Scheme & Ordering Guide

ATC200-Lite Teletilt® Remote Control Downtilt System

10.2 Ordering Guide

As an example, assume a system is to be ordered for deployment in North America. The site is a three sector site employing three UMWD-06516-XDM antennas. For this example, let’s say the distance from the local controller to the junction box is 77m and the distance from the junction box to the three actuators is 2 meters. This system would require the following.

Quantity

Part Number

Description

 

 

 

1

ATC200-Lite-0004

Local Controller

1

ATJB200-A01-004

4-Way Junction Box

3

ATM200-001

Actuators

Optional

ATLP-200-001

Lightning Protection Unit

1

ATCB-B01-080

80 Meter Cable

3

ATCB-B01-004

4 Meter Cables

1 or more

602299

Grounding Kit

2

40417

Tiewraps, Bag of 50

 

 

 

The 80 m length is selected since it is the smallest size greater than 77 m. Field fitting of connectors is not recommended in order that reliable, weatherproof connections can be maintained.

Although the distance between antennas is 2 m, you will generally require a cable longer than this ‘straight line’ distance.

The junction box requires grounding. If a lightning protection unit is used, it must also be grounded.