Chapter 4 Measurements

Step 14. Verify the measured insertion loss against the calculated insertion loss:

 

Type

Attenuation (dB/ft)

￿ Length (ft)

= Loss (dB)

First Jumper

LDF4-50A

0.0325

20

0.65

 

 

 

 

 

Main Feeder

LDF5-50A

0.0186

150

2.79

 

 

 

 

 

Top Jumper

LDF4-50A

0.0325

10

0.325

 

 

 

 

 

The number of connector pairs (3) times the loss per pair (in dB) equals the con- nector loss: 3 ￿ 0.14 = 0.42.

The insertion loss of the transmission system is equal to:

First Jumper loss + Main Feeder Loss + Top Jumper Loss + Connector Loss = Insertion Loss

0.65

+

2.79

+

0.325

+ 0.42

= 4.19 dB

Figure 4-3is an example of a typical transmission line cable loss trace.

Figure 4-3. Typical Transmission Line Cable Loss Trace