Chapter 4 Measurements

Step 8. Press the SYS key, then OPTIONS, then BIAS TEE to turn on the bias tee volt- age. The gain is the level change before and after the bias tee voltage is turned on.

Step 9. Press the AUTO SCALE key, or press the AMPLITUDE key to adjust the top and bottom scale, to display the gain level.

Step 10. Press the MARKER key and set marker set M1 to 834 MHz and marker M2 to 883 MHz.

REFERENCE LEVEL

GAIN MEASURED WITH

AFTER CALIBRATION

BIAS TEE ACTIVATED

 

Gain/Insertion Loss

2-PORT CAL

 

 

 

M1: .01 dB @ 833.68 MHz

 

 

M2: .00 dB @ 882.99 MHz

 

15

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

dB

 

 

 

 

 

 

 

 

 

 

 

0

Limit : 0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M1

 

 

 

 

M2

 

-10

 

 

 

 

 

 

 

 

 

 

 

 

800

810

820

830

840

850

860

870

880

890

900

 

 

 

 

 

Frequency (800.0 - 906.0

 

 

 

Resolution: 130

CAL: ON(COAX)

Date: 06/13/2001

Time: 15:52:43

Gain/Insertion Loss

 

 

 

 

 

 

TMA

 

 

 

 

 

20

 

M1: 12.90 dB @ 833.68 MHz

M2: -.92 dB @ 882.99 MHz

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

0

Limit : 0.00

 

 

 

 

 

 

 

 

 

-10

 

 

 

 

 

 

 

 

 

 

 

-20

 

 

 

 

 

 

 

 

 

 

 

dB-30

 

 

 

 

 

 

 

 

 

 

 

-40

 

 

 

 

 

 

 

 

 

 

 

-50

 

 

 

 

 

 

 

 

 

 

 

-60

 

 

 

 

 

 

 

 

 

 

 

-70

 

 

 

 

M1

 

 

 

M2

 

 

 

 

 

 

 

 

 

 

 

 

800

810

820

830

840

850

860

870

880

890

900

 

 

 

 

Frequency (800.0 - 906.0 MHz)

 

 

Resolution: 130

CAL: ON(COAX)

Date: 06/13/2001

Time: 15:38:07

Figure 4-9. TMA Gain Measurement After Calibration

Marker M1 set at 834 MHz indicates the receive band of the tower mounted amplifier. The level above the 0 dB reference level is the gain of the TMA. Marker M2 set at 883 MHz in- dicates the transmit band of the amplifier where there is no gain.

Gain/Insertion Loss

TMA-S CELLULAR

(dB)

20

M1: 13.57 dB @ 836.82 MHz

 

 

 

 

 

10

 

 

 

 

 

 

 

 

Transmission

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20

 

 

 

 

 

 

 

 

 

-30

 

 

 

 

 

 

 

 

 

-40

 

 

 

 

 

 

 

 

 

-50

 

 

 

 

 

 

 

 

 

-60

 

 

 

 

 

 

 

 

 

-70

 

 

 

 

M1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

775

800

825

850

875

900

925

 

 

 

 

Frequency (750.0 - 925.0 MHz)

 

 

Figure 4-10. TMA-S Gain Measurement

4-14

Page 59
Image 59
Anritsu S251C manual TMA Gain Measurement After Calibration