Anritsu S251C General Information, 1. Performance Specifications 1 of, Description Site Master

Models: S251C

1 81
Download 81 pages 12.93 Kb
Page 11
Image 11
Table 1-1.Performance Specifications (1 of 2)

Chapter 1 General Information

Table 1-1.Performance Specifications (1 of 2)

Specifications are valid when the unit is calibrated at ambient temperature after a 5 minute warmup.

Description

Site Master:

S251C

Frequency Accuracy (RF Source Mode):

Frequency Resolution:

SWR:

Range

Resolution

Return Loss:

Range

Resolution

**Distance-To-Fault (DTF): Range (in meters) Resolution (in meters) (Rectangular Windowing)

Insertion Loss/Gain

Range:

Resolution

RF Source

Frequency

Power Output (nominal)

RF Power Monitor:

Range

Offset Range

Resolution

Value

Frequency Range:

625 to 2500 MHz

￿75 parts per million @ 25°C*

10 kHz

1.00to 65.00

0.00to 54.00 dB

0.01dB

0 to (Resolution x (dp–1)) a maximum of

1000m (3281 ft.) with a maximum of 517 points resolution, # of data pts. = 130, 259, 517

(1.5 ￿ 108)(Vf )

￿F

Where Vf is the relative propagation velocity of the cable .

dp is the number of data points (130, 259, 517).

￿F is F2 - F1 (in Hz.)

–90.00 to +50.00 dB 0.01 dB

625 to 2500 MHz @ 10 kHz step selectable, – 30 dBm or + 6 dBm

–80.0 to +80 dBm or

10.0pW to 100.0 kW 0 to +60.0 dB

0.1dB or

0.1xW

Test Port, Type N

50 Ohms

 

***Immunity to Interfering signals

 

 

up to the level of:

 

 

on-frequency

RF out

+10 dBm, reflection

 

RF in

+30 dBc, transmission

on-channel

RF out

+17 dBm, reflection

Maximum Input (Damage Level):

 

 

Test Port, Type N

+22 dBm

 

RF Detector

+20 dBm

 

Measurement Accuracy:

Measurement accuracy depends on calibration components. Precision calibration load provides a corrected directivity of 42 dB.

1 - 4