Chapter 4 Measurements

Distance-To-Fault (DTF) Transmission Line Test

The Distance-To-Fault transmission line test verifies the performance of the transmission line assembly and its components and identifies the fault locations in the transmission line system. This test determines the return loss value of each connector pair, cable component and cable to identify the problem location. This test can be performed in the DTF–RE- TURN LOSS or DTF–SWR mode. Typically, for field applications, the DTF–RETURN LOSS mode is used. To perform this test, disconnect the antenna and connect the load at the end of the transmission line.

Required Equipment

￿Site Master Model S251C

￿Precision Open/Short, Anritsu 22N50 or Precision Open/Short/Load, Anritsu OSLN50LF

￿Precision Load, Anritsu SM/PL

￿Test Port Extension Cable, Anritsu 15NNF50-1.5C

￿Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M)

Device Under Test

￿Transmission Feed Line with Load

Procedure - DTF-Return Loss Mode

The following steps explain how to make a DTF measurement in return loss mode.

Step 1. Press the MODE key.

Step 2. Select DTF-RETURN LOSS using the Up/Down arrow key and press ENTER. Step 3. Set the start and stop frequencies, F1 and F2, as described on page 3-2.

Step 4. Connect the Test Port Extension cable to the RF Out port and calibrate the Site Master as described on page 3-2.

Step 5. Save the calibration set up (page 3-5).

Step 6. Connect the Device Under Test to the Site Master phase stable Test Port Exten- sion cable. A trace will be displayed on the screen as long as the Site Master is in sweep mode.

Step 7. Press the FREQ/DIST key.

Step 8. Set the D1 and D2 values. The Site Master default for D1 is zero.

Step 9. Press the DTF AID soft key and select the appropriate CABLE TYPE to set the correct propagation velocity and attenuation factor.

NOTE: Selecting the right propagation velocity, attenuation factor and distance is very important for accurate measurements, otherwise the faults can not be identified accurately and insertion loss will be incorrect.

Step 10. Press SAVE DISPLAY (page 3-5) name the trace, and press ENTER.

Step 11. Record the connector transitions.